Electric Unit Digital Soldering Iron Station Temperature Controller Kits for HAKKO T12 Handle DIY kits w/ LED vibration switch

Save $8.00

Color-: Blue LED
Price:
Sale price$16.28 Regular price$24.28

Description


Please read the description before order!


The kit is a DIY product, T12 tip will be different from the random purchase, T12 tip can be used for HAKKO T12 handle, quality assurance, customers can rest assured to buy. We are the DIY kits, not kits produced by HAKKO.
 
Question:if display show 500,T12 tip not heat up,hope you can check again the handle and vibration switch like our manual or video,because if the T12 tip not insert or the handle wrong connect,it will show 500!

pay attention:when soldering the handle or others like our manual,can not touch each other

Question: the temperature does not correspond to reality, the display is 200 ° with and in fact the temperature of the tip is 300 ° sec. Why is that?

Answer :see the following,change P03 and P07
 
The Package listing as the main photo shows all diy kit(But If you chooseABS shellor24V4.5A power supply switching transformer,the package only the part you choice not the DIY kits!)
We suggest not order theShelltogether withthe following24V 4A 6A power supply switching transformer(we don't sell this power supply now),because it need  you to change the shell to have enought place for Power supply,you can do like the following photo as my other Customers do!(you can choose our new 4.5A power supply)

 

Question: the temperature does not correspond to reality, the display is 200 ° with and in fact the temperature of the tip is 300 ° sec. Why is that?

Answer :see the following,change P03 and P07

Controller parameter setting mode:

(The default has been set, no special requirements, please do not set up a random)

Press and hold the encoder button does not move → start → enter the parameter settings mode:


There are 12 menus available for setup,P00,P01,P02,P03,P04,P05,P06,P07,P08,P09,P10,P11.The digital display menu is 1.5 seconds,and then automatically displays the corresponding parameters of this menu,at the same time rotate left encoder is reduced,right is increase,Press it and automatically save the currently set parameters.And then display the next menu for 1.5 seconds, and then display the corresponding parameters of this menu, and so on. When all parameters are set to automatically enter the normal heating mode.

Because each set a parameter to save once, so you can shut down at any time without having to set all the parameters (such as you just want to set P01, set P01 after you can shut down and then boot into normal mode)

Menu item:

P00: restore the default parameters (0 or 1, the default value of 0,0 for not recovering, 1 for the recovery)

P01: Operational amplifier gain (200 to 350 times, step 1, default 230)

P02: Operational amplifier offset voltage (0 ~ 250mV, step 2, the default value of 100, refers to the tip to keep the room temperature operational amplifier inherent output voltage, according to my measurement this voltage varies greatly with temperature, different magnification Not the same, the higher the magnification, if you do not measure, please keep the default value)

P03: thermocouple ℃ / mV data (30 ~ 50, step 1, the default value of 41, refers to the thermocouple need to temperature how much voltage was increased by 1mV, according to the type of thermocouple self-calculation, if you do not understand, please keep Defaults)

P04: temperature adjustment step (0,1,2,5,10 degrees optional, 0 can lock the soldering iron temperature)

P05: sleep time (how long don’t not move into sleep) (0 ~ 60 minutes, step 1, 0 is to forbidden the sleep function)

P06: Shutdown time (0 ~ 180 minutes, 0 ~ 30 step 1,30 ~ 180 step 10, 0 is forbidden shutdown function)

P07: temperature correction (+20 degrees, step 1) (due to NTC resistance in the chassis, the soldering station heat will lead to the detection of NTC temperature higher than room temperature, resulting in high temperature compensation of the thermocouple, soldering iron temperature is not accurate,or other causes the temperature is not accurate.If you set the other parameters are correct value but the temperature is still high or low, you can use this parameter correction.For example, to detect the displayed soldering iron temperature is 20 degrees higher than the actual value of this parameter Set to 20)

P08: wake mode (0,1, 0 in the shutdown mode can be rotated the encoder and also can shake the handle to wake up, 1 can only rotate the encoder wake up (Note: press the encoder can not wake up, can only rotate) )

P09: temperature increase mode to increase the temperature to adjustable (20 degrees to 100 degrees adjustable, adjust the pace of 10 degrees)

P10: temperature to increase the duration to adjustable (adjustment range of 10 seconds to 250 seconds, adjust the step 5 seconds)

P11: Parameter setting mode Auto save parameter and return to heating mode Function to active time adjustable (range 4 seconds to 60 seconds)

You may also like

Recently viewed